LJTPQ00RE-25-37A-014 Product Introduction:
Amphenol Aerospace Operations Part Number LJTPQ00RE-25-37A-014(Circular Connectors - Housings), developed and manufactured by Amphenol Aerospace Operations, distributed globally by Jinftry. We distribute various electronic components from world-renowned brands and provide one-stop services, making us a trusted global electronic component distributor.
LJTPQ00RE-25-37A-014 is one of the part numbers distributed by Jinftry, and you can learn about its specifications/configurations, package/case, Datasheet, and other information here. Electronic components are affected by supply and demand, and prices fluctuate frequently. If you have a demand, please do not hesitate to send us an RFQ or email us immediately sales@jinftry.com Please inquire about the real-time unit price, Data Code, Lead time, payment terms, and any other information you would like to know. We will do our best to provide you with a quotation and reply as soon as possible.
Circular Connectors - Housings are an important part of circular connectors that provide physical support and protection for connectors. This housing is usually made of metal or high-strength plastic, which ensures the stable operation of the connector in complex and changeable environments. The design of the circular connector housing takes into account mechanical strength, electromagnetic shielding, protection level and other factors to meet the needs of different applications.
Application
Circular Connectors-Housings In the field of industrial automation, circular connector housings have become an indispensable part of connecting various automation equipment and control systems because of their durability and easy maintenance. In the aerospace industry, in the face of extreme environmental conditions and demanding performance requirements, the circular connector housing ensures the reliable operation of the connector in extreme conditions such as high altitude, high speed, high temperature and low temperature by using high-strength materials, special surface treatment and precision sealing design. In addition, in many industries such as automotive electronics, medical equipment, communication equipment, energy and power, the circular connector shell also plays a key role, providing a solid guarantee for the stable connection and efficient operation of electrical and electronic equipment.
FAQ about Circular Connectors - Housings
-
1. How to install the circular connector housing?
1. Welding installation: This installation method requires the metal housing of the circular connector and the welding points of the equipment to be cleaned and polished to ensure the quality of welding, so as to achieve a firm connection to the equipment. The characteristics of welding installation are firm installation and reliable connection, which is suitable for application scenarios with high requirements for connection strength.
2. Threaded installation: Threaded installation is to fix the circular connector through threads. This installation method is simple and can select the appropriate thread specifications and lengths according to the size and requirements of the equipment to ensure that the connector is firmly fixed. The characteristics of threaded installation are easy installation and replaceability, which is suitable for situations where frequent replacement is required or installation speed is required.
-
2. How to distinguish the male and female connectors?
1. Appearance difference: Male connectors usually have protruding pins, while female connectors have recessed slots. This is one of the most common ways to distinguish.
2. Marking difference: Some connectors may have markings on the shell, such as "M" for female and "F" for male.
3. Internal structure difference: In some special cases, the internal structure of male and female connectors is also different.
Of course, the most reliable way is to check the specifications and technical information of the connector, which usually clearly indicate the gender of the connector.
-
3. Connector housing spring positive force setting requirements?
1. Insertion and extraction force test:
The test object is the entire connector, including all components.
The test action axis is the direction of normal use of the connector.
Unless otherwise specified, the test speed is defined as 25.4mm/minute.
Insertion force is generally set to a maximum value (35N Max.).
Pull-out force is generally set to a minimum value (7N Min. initial; 3N Min. Final), and some customers also require a maximum value.
2. Locking force test:
The purpose is to confirm that the contact interface of the connector does not separate when subjected to unexpected forces to ensure functionality under unexpected conditions.
Generally set to a minimum value (30N Min.).
3. Retention force test:
This part is not explicitly mentioned in the search results provided, but according to the general test requirements for connectors, retention force may involve measuring the ability of the connector to maintain its connection state under specific conditions.